Spectrophotomčtres UV-VIS
 

 

UV-VIS Spectrophotometers
 

 

Scinco

  Series S-3100
  The PDA spectrophotometers with great value for money.
  • S-3100:  high performance PDA spectrophotometer.

    Full specifications
    (0.7 MB)
    The S-3100 Series is the standard measurement instrument to satisfy such customer requirements. By integrating hardware and sofrware from SCINCO, a company with a proven history of innovation in PDA UV-Vis instrumentation, the S-3100 Series makes the accuracy of a research-grade spectrophotometer accessible to all laboratories. Offering a standard interface configuration utilizing USB port to ensure fast communication, the S-3100 Series facilitates your research. In addition, the control of data by LabPro Plus Software enhances the performance of SCINCO PDA UV-Vis Spectrophotometers. While it is easy to learn and integrate with existing lab operations, the S- 3100 Series also offers new-generation innovations and ease-of-use features that improve the quality of results, while boosting overall laboratory productivity.
  • Dual Lamp Source Consists of an in-line Deuterium and tungsten dual lamp system that maintains high-intensity light in the range of 190 to 1100 nm. It increases the energy intensity while utilizing a minimal optical path. The "see-through" optical design gives increased reliability and also provides a perfect, seamless transition from UV to Visible wavelengths. Photometric accuracy is thus assured, giving you maximum confidence in your results.
  • Photodiode Array (PDA) Detector The photodiode array(PDA) detector provides an efficient analytical environment in which you can obtain a reliable data through superior reproducibility, high accuracy and an integrating function. It helps you to obtain fast data acquisition and to be able to detect multi-wavelength at the same time. It is also very useful for rapidly changing samples. The 1024 channel PDA detector provides a spectral bandwidth of 0.75nm (S-3130) or 0.95nm (S-3150).
  • Flexibility for Variable Inbterfaces The S-3100 Series is designed to allow a higher stability through RS-232C interface between spectrophotometer and the PC and the rapid communications enable maximum data to be acquired. Thus, the S-3100 Series can be effectively used in applications such as Kinetics, enzyme activity, Protein research and DNA analysis, etc.
  • Modular Structure The electronic and optical components of the S-3100 Series are designed as a unique modular system. This modular design facilitates easy maintenance and service.
  • LabPro Plus Software LabPro Plus Software is a powerful tool for collecting and processing data in a wide variety of applications. LabPro Plus Software allows you to easily acquire and analyze the highest quality data from S-Series PDA UV-Vis Spectrophotometer. Instrument validation is performed quickly and easily to quarantee best results. LabPro Plus Software also provides diverse protein methods and DNA Analysis in our Bio Package. Protein methods include Bradford, BCA, Biuret, Lowry, TBA, and Direct UV. LabPro Plus Software is compatible with windows 98/ME/2000 or XP. Built-in data conversions and formats provided efficiently support Lab Pro and LabPro Easy files, CSV, XLS, BMP and WMF. LabPro Plus data is easily exported into Excel and other Windows programs.
  • Specification
  • Model : S-3130 (S-3150)
  • Sources : Pre-aligned Tungsten & Deuterium Lamp
  • Lamp Detector : 1024 channel PDA
  • Wavelength Range : 190 ~ 850 nm (190 ~ 1100 nm)
  • Wavelength Reproducibility : ±0.02 nm
  • Wavelength Resolution : 0.75 nm (0.95 nm)
  • Data Acquisition Mode : AU, %T, %R, Intensity, Concentration
  • Photometric Range : -3.0 ~ 3.0 AU
  • Scan Speed : 0.02 sec for full wavelength range
  • Integration Time : 0.02 ~ 6 sec
  • Dimension : 52.1 (W) ×23.1 (H) ×45.0 (D) cm, 14 kg
  • Power Voltage ranges : 110 or 220 V ±10 %, free of spikes Current
  • Environmental Operating temperature : 5°C~40°C
  • Humidity : less than 95 % relative, non-condensing.
  • Use Identification, Multi-Component Analysis, Quantitative Analysis, Kinetic Experiment, Protein Quantification, DNA Analysis.

     
SO-S3130
SO-S3150
reference
     
S-3130
S-3150
name
     
190 - 850
190 - 1100
(nm)
wavelength
     
0.01
0.01
(nm)
resolution
     
0.75
0.95
(nm)
bandwith
     
± 0.02
± 0.02
(nm)
reproducibility
     
-3.0 - +3.0
-3.0 - +3.0
(AU)

photometic range

     
AU, %T, %R, Intensity, Concentration
AU, %T, %R, Intensity, Concentration
( - )
units
     
< 0.05*
< 0.05*
(%T)

stray light *@340 & 220nm

     
0.02**
0.02**
(s)
scan speed *for full wavelength range
     
yes
yes
( - )
RS-232
       
Best performance!
 
(CHF)
price
 
S-3100:  high performance PDA spectrophotometer.
S-3100:  high performance PDA spectrophotometer.
only!
  Communication cable (RS-232/USB), mains lead, cell holder and instruction manual.   included
  Option accessories: Peltier temperature controller, cells & cell holders, auto sampler and sipper system, refrigerated circulator, LabPro Plus software, transmission dip probe and many others.    

 

  Model 6800
  The high-end double-beam spectrophotometers with great value for money.
  • Model 6800: double-beam scanning  spectrophotometer.

    Full specifications
    (5.5 MB)
    The Jenway Model 6800 is built on a solid foundation of high quality, sealed optics for optimum photometric performance. The user-friendly Flight Deck software delivers the intuitive operation you have come to expect from Jenway instruments; while the operator-focus ensures this spectrophotometer will meet the demands of your laboratory, today and into the future.
  • True Double Beam with highly stable optics
  • 1.5nm spectral bandwidth Includes
  • Jenway Flight Deck Software
  • A range of easy to fit accessories.
  • Operating modes include:
  • Photometrics/Multi-Wavelength Measure the absorbance or transmittance at one to six wavelengths. The dedicated 'Ratio Mode' allows calculation of the ratio and difference of two or three selected wavelengths. An alphanumeric identity can be entered for each sample. All results are displayed in a simple tabular format for quick and easy export to Excel®, other spreadsheets or databases.
  • Spectrum Scanning Scan in the range 190 to 1100nm with resolutions of up to 0.1nm and scan speeds up to 3600nm/sec. All data is displayed in both graphical and tabular formats with automatic peak and valley identification as well as manual selection. Post scan manipulations allow multiple overlays, spectrum calculations and derivative spectra to be displayed.
  • Time Scan and Kinetics Measure the changes in absorbance or transmittance over 30 to 99999 seconds. The concentration or activity values can then be calculated from the display by the free selection of a start and end time for which a regression curve is displayed and calculations made against an adjustable K factor.
  • Quantitation Enables the accurate measurement of sample concentrations against calibration curves (K factor, 1st to 3rd order) based on up to twenty standards and up to three wavelengths for multi-component analysis. The easy recall of saved calibration curves leads to quicker, more accurate analysis.
  • DNA/RNA Offers standard methods for measuring DNA, RNA or oligonucleotide concentrations using the absorbance values recorded at 260 and 280nm. The micro cell holder accessory (680 031) allows the accurate measurement of sample volumes down to 50µL.
  • Protein Offers pre-set methods for measuring protein concentration using the Bradford, Lowry, BCA and Direct UV protocols. Any of the default settings can be modified allowing specific user variations to any of these standard test protocols.
  • Exporting to Excel By simply clicking the dedicated 'Export to Excel' icon the Jenway 6800 Flight Deck software automatically exports raw data and results to Excel® for further processing or saving.

 
JW680-SC
Model 6800-MC
Model 6800-LC
Model 6800-TC
reference
 
Model 6800-SC
Model 6800-MC
Model 6800-LC
Model 6800-TC
name
 
190 - 1100
190 - 1100
190 - 1100
190 - 1100
(nm)
wavelength
 
0.1
0.1
0.1
0.1
(nm)
resolution
 
1.5
1.5
1.5
1.5
(nm)
bandwith
 
< 0.05*
< 0.05*
< 0.05*
< 0.05*
(%T)

stray light *@340 & 220nm

 
ppb, ppm, µg/l, mg/l, M, %, blank
ppb, ppm, µg/l, mg/l, M, %, blank
ppb, ppm, µg/l, mg/l, M, %, blank
ppb, ppm, µg/l, mg/l, M, %, blank
( - )
units
 
Photometrics (includes Multiwavelength), Spectrum, Kinetics and Time Scan, Quantitation, DNA/RNA and Protein
Photometrics (includes Multiwavelength), Spectrum, Kinetics and Time Scan, Quantitation, DNA/RNA and Protein
Photometrics (includes Multiwavelength), Spectrum, Kinetics and Time Scan, Quantitation, DNA/RNA and Protein
Photometrics (includes Multiwavelength), Spectrum, Kinetics and Time Scan, Quantitation, DNA/RNA and Protein
( - )
operation modse
 
±0.001A
±0.001A
±0.001A
±0.001A
(A)
photometric reproducibility
 
0.0003A/hour
0.0003A/hour
0.0003A/hour
0.0003A/hour
(A)
baseline stability
 
yes
yes
yes
yes
( - )
GLP
 
yes
yes
yes
yes
( - )
RS-232
 

Single Cuvette holder (10×10mm)

Micro Cuvette holder
Long Path Length Cuvette holder (for 10, 20, 30, 40, 50 or 100mm cuvettes)
Water Thermostated Cuvette holder (10×10mm)
( - )
cuvette holder
       
 
PC Not supplied but required.
(CHF)
price
 
Model 6800: double-beam scanning  spectrophotometer.
Model 6800: double-beam scanning  spectrophotometer.
Model 6800: double-beam scanning  spectrophotometer.
Model 6800: double-beam scanning  spectrophotometer.
only!
             
  Mains lead, cell holder, Flight Deck PC Software on CD ROM, interconnection cable and instruction manual.   included
  Option Accessories micro-cell holder, water heated cell holder, film and glass filter holders, a long path cell holder, sipper pump, Peltier heated cell system, temperature controlled sipper system, cells, vacuum pump, external Peltier cooler, water circulator, calibration standards set, micro-cuvettes, flow-through cuvettes and many others.    

 

  Model 6500/6505
  The high-end spectrophotometers with great value for money.
  • Model 6500/6505: scanning  spectrophotometer.

    Full specifications
    (1.1 MB)
    The 6500 series are multi-capability scanning spectrophotometers designed to provide the user with a high quality system which offers all the features required by a scientist to manipulate and process spectral information. The Model 6500 Visible range unit operates at 320-1100nm. The Model 6505 UV/Visible range unit operates at 190-1100nm.
  • High performance split beam optics
  • 1.8nm bandwidth
  • Spectral addition and subtraction
  • 1st-4th derivative and post scan analysis
  • Method and results storage
  • Application and data storage cards.
  • A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
  • Simple keypad layout and operating protocols facilitates the setting of experimental parameters and initiating sample analysis procedures.
  • Graphical user interface (GUI) allows interactive control of all operating parameters. Both keypad and mouse operation are fully supported.
  • Multi-language capability allows screen instructions to be presented in a choice of English, French, German, Italian, Portuguese and Spanish.
  • Five operating ranges are available - photometrics, spectrum, kinetics, multi-wavelength and quantitation. Full kinetics capability allows, usually in conjunction with the peltier cell block, full analysis of timed reactions.
  • .Calibration curves producing non-linear results can also be accommodated using in-built software. Up to twenty data points (standards), or up to seven when using the multi-cell changer, can be determined automatically and used to construct a calibration curve. A variety of statistical methods are available to ensure a close correlation to all curve shapes.
  • Full interfacing capability using RS232 interfacing or an analogue output is provided as standard. Utilising the RS232 facility allows results to be down loaded via the front panel print key. Both models incorporate a bi-directional interface allowing remote operation, calibration and interrogation by an external computer.
  • A versatile sample compartment is fitted to the instrument to house the full range of accessories developed for the 6500 series.
  • An integral printer module is available and can be supplied as a factory fitted item at the time of ordering the product or as a customer installable module.
  • Full scanning capability allows scan range, speed and resolution to be user adjusted and the resultant scan to be auto scaled for enhanced visibility. Peaks and valleys are labelled with wavelength and absorbance values and can be readily down loaded to the optional internal printer, to a PC or a Centronics printer. A cursor facility allows the user to interrogate specific parts of the scanned data.
  • An automatic results log allows readings to be stored in a data file either when the print key is pressed; at a user defined set time interval or by a multiple sample assay using the 8 position cell holder. Data files have a user entered ID and can be saved in internal memory or to an external data card. Results saved in internal memory can be transferred to an external data card.
  • Method storage allows all user set parameters to be saved against a user identification. A method can be subsequently recalled which configures the instrument to the saved parameters. The instrument settings for a recalled method can be altered and subsequently saved against the same or a different method identification. Methods can be saved in internal memory or to an external memory card. Methods saved in internal memory can be transferred to an external data card. The instruments memory has the capacity to store a minimum of fifty methods.
  • Traceable calibration standards provide the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). A user set identification number (up to 20 digits in length) is entered and will be shown on any printouts produced by the instrument. In addition, each printout will show sample number, reading, unit of measurement, the wavelength analysis and the current time and date. Scans and concentration curves stored will also be time and date stamped. The 6500 series complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility.

     
JW650001
JW650501
reference
     
Model 6500
Model 6505
name
     
320 - 1100
190 - 1100
(nm)
wavelength
     
0.1
0.1
(nm)
resolution
     
1.8
1.8
(nm)
bandwith
     
< 0.05*
< 0.05*
(%T)

stray light *@340 & 220nm

     
ppb, ppm, µg/l, mg/l, M, %, blank
ppb, ppm, µg/l, mg/l, M, %, blank
( - )
units
     
yes
yes
( - )
GLP
     
yes
yes
( - )
RS-232
       
 
The built-in printer is an option.
(CHF)
price
 
Model 6500/6505: scanning  spectrophotometer.
Model 6500/6505: scanning  spectrophotometer.
only!
             
  Mains lead, serial mouse, mouse mat, pack 100 disposable cuvettes (3.5 ml), 8 position multi-cell changer and instruction manual.   included
  Option accessories sipper pump, Peltier heated cell system, temperature controlled sipper system, cells, vacuum pump, external Peltier cooler, water circulator, calibration standards set, micro-cuvettes, flow-through cuvettes and many others.    

 

  Model 6400/6405
  The efficient spectrophotometers with great value for money.
  • Model 6400/6405: scanning  spectrophotometer.

    Full specifications
    (1.2 MB)
    The 6400 series incorporate a wide range of features designed to satisfy the needs of users seeking to maximise the efficiency of routine and specialised UV and visible spectroscopy tasks. The Model 6400 Visible range unit operates at 320-1100nm. The Model 6405 UV/Visible range unit operates at 190-1100nm.
  • Single beam scanning
  • 5nm bandwidth
  • Multi-wavelength and kinetics analysis
  • Wide range of sampling accessories
  • Full interfacing capability
  • Optional 8 position multi-cell changer (quantitation measurement).
  • A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
  • Simple keypad layout and operating protocols facilitates the setting of experimental parameters and initiating sample analysis procedures.
  • Multi-language capability allows screen instructions to be presented in a choice of English, French, German, Italian, Portuguese and Spanish.
  • Calibration curves producing non-linear results can also be accommodated using in-built software and the multi-cell changer. Up to seven data points can be determined automatically and used to construct a calibration curve. A variety of statistical methods are available to ensure a close correlation to all curve shapes.
  • Five operating ranges are available - photometrics, spectrum, kinetics, multi-wavelength and quantitation. Full kinetics capability allows, usually in conjunction with the peltier cell block, full analysis of timed reactions.
  • Full interfacing capability using RS232 interfacing or an analogue output is provided as standard. Utilising the RS232 facility allows results to be down loaded via the front panel print key. Both models incorporate a bi-directional interface allowing remote operation, calibration and interrogation by an external computer.
  • An integral printer module is available and can be supplied as a factory fitted item at the time of ordering the product or as a customer installable module.
  • Full scanning capability allows scan range, speed and resolution to be user adjusted and the resultant scan to be auto scaled for enhanced visibility. Peaks and valleys are labelled with wavelength and absorbance values and can be readily down loaded to the optional internal printer, to a PC or a Centronics printer. A cursor facility allows the user to interrogate specific parts of the scanned data.
  • Traceable calibration standards provide the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). A user set identification number (up to 20 digits in length) is entered and will be shown on any printouts produced by the instrument. In addition, each printout will show sample number, reading, unit of measurement, the wavelength analysis and the current time and date. Scans and concentration curves stored will also be time and date stamped. The 6500 series complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility.

     
JW640001
JW640501
reference
     
Model 6400
Model 6405
name
     
320 - 1100
190 - 1100
(nm)
wavelength
     
0.1
0.1
(nm)
resolution
     
5
5
(nm)
bandwith
     
< 0.5*
< 0.5*
(%T)

stray light *@340 & 220nm

     
ppb, ppm, µg/l, mg/l, M, %, blank
ppb, ppm, µg/l, mg/l, M, %, blank
  units
     
yes
yes
( - )
GLP
     
yes
yes
( - )
RS-232
       
Best lab use!
 
 
The built-in printer is an option.
(CHF)
price
 
Model 6400/6405: scanning  spectrophotometer.
Model 6400/6405: scanning  spectrophotometer.
only!
       
   
  Mains lead, pack 100 disposable cuvettes (3.5 ml) and instruction manual.   included
  Option accessories sipper pump, Peltier heated cell system, temperature controlled sipper system, cells, vacuum pump, external Peltier cooler, water circulator, calibration standards set, micro-cuvettes, flow-through cuvettes and many others.    

 

  Model Genova Life Science Analyser
  The dedicated spectrophotometers to DNA, protein, direct photometric analysis with great value for money.
  • Genova: Life science analyser.

    Full specifications
    (0.1 MB)
    The Genova is designed for the scientist whose primary interest is the study of DNA and proteins. Operation is simple and quick, with all routinely used DNA calculations being pre-programmed into the product. The Genova employs a precision built diffraction grating to select wavelengths and narrow bandwidth, thus avoiding the limited capability of filter based units. Three independent wavelength calibrations are performed during the start-up protocol to guarantee optimum confidence in results and to satisfy G.L.P. procedures.
  • Genova Life Science Analyser - DNA
  • Immediate answers to DNA purity
  • Pre-programmed for user selectable absorbance ratios
  • Direct readout of dsDNA, ssDNA, RNA and Oligo purity
  • Purity scan mode.
  • Optimised for low volume analysis the determination of DNA levels as low as 70ng with sample volumes as low as 20 µl is possible using the capillary sampling accessory. The Genova will automatically calculate ratios at 260/280 or 260/230 with an optional substraction of a third wavelength (typically 320 nm). Alternatively, pre-programmed factors allow direct readings of ssDNA, dsDNA, RNA and Oligonucleotides.
  • Genova Life Science Analyser - Protein
  • Standard pre-programmed parameters for B.C.A, Bradford, Biuret, Lowry and direct measurement
  • Storage of calibration curves
  • Versatile open architecture that allows other wavelengths and accessories for other assays to be performed.
  • The on-board software allows all protein methodologies to be optimised and run on the Genova with a minimum of set-up time. These methodologies can then be viewed on the display for easy interpretation of linearity of response. The Genova has the versatility to change these parameters easily for the scientist who wants to optimise their analysis with different wavelength, curve or constant.
  • Genova Life Science Analyser - Direct Photometric
  • For modes of operation where DNA or protein analysis is not required the Genova can be used in direct photometric mode. In this mode concentration, with a choice of units, as well as the absorbance, transmission and wavelength are displayed.

       
JW636001
reference
       
Model Genova
name
       
198 - 1000
(nm)
wavelength
       
1
(nm)
resolution
       
5
(nm)
bandwith
       
< 0.5*
(%T)

stray light *@340 & 220nm

       
ppm, mg/l, g/l, M, %, µg/l, µg/ml, mg/ml, ng/ml, mM, blank
  units
       
yes
( - )
GLP
       
yes
( - )
RS-232
         
 
   
(CHF)
price
 
Genova: Life science analyser.
only!
  Mains lead, 8 x semi-micro plastic cuvettes, cell holder and instruction manual.   included
  Option accessories capillary micro-sample holder, sipper pump, 4 position cell holder, interface cable kit, calibration standards set, micro-cuvettes and many others.    

 

  Model AquaNova Environmetal Spectrophotometer
  The dedicated spectrophotometers to environmental analysis with great value for money.
  • AquaNova: environmental spectrophotometer.

    Full specifications
    (0.1 MB)
    Dedicated to water & environmental testing
  • Open system for use with most test kits
  • Up to 300 test methods held in memory
  • Test manager offers step-by-step guide
  • Includes PC software
  • Down load tests from CD ROM or Internet
  • Aquanova is designed for water testing and environmental applications, complete with an impressive 300 method memory to store all of the standard photometric tests.
  • Aquanova is an open system and can be used with test kits and reagents from almost any supplier. Test methods can be recalled by browsing alphabetically, from selected index letters, or from a list of the most recently used tests in the Dynamic Journal that is automatically updated each time a test is selected.
  • Aquanova is supplied pre-loaded with the test methods for Jenway kits, but can be easily programmed either manually, using the instrument keypad, or by down load from the Aqua-link PC software and CD supplied (the latest updates are available for down load from the Jenway website www.jenway.com).
  • Method Development is also possible on Aquanova as each test method can have up to six calibration standards, ensuring that even test methods with a non-linear response can be catered for.
  • To ensure optimum performance, Aquanova runs a detailed self-diagnostic and calibration check every time the unit is switched on. Prompts, information boxes and diagnostic codes guide you through all the operational procedures.

       
JW637001
reference
       
Model AquaNova
name
       
320 - 1000
(nm)
wavelength
       
1
(nm)
resolution
       
8
(nm)
bandwith
       
< 0.5
(%T)

stray light

       
300
( - )

test memory

       
50
( - )

result memory

       
6
( - )

calibration curve

       
mg/l, g/l, blank, %, ppm, pH, mg/kg, IFZ, HZ, Meq, U/ml, mU/l, µM/l, mM/l, M/l, µg/ml, mg/ml, µg/dl, g/dl, ng/l, µg/l
  units
       
yes
( - )
PC software
       
yes
( - )
RS-232
         
 
   
(CHF)
price
 
AquaNova: environmental spectrophotometer.
only!
  Mains lead, 9 way serial cable,PC Application Software on CD ROM, and instruction manual.   included
  Option accessories various test kits, digestor, sample holders, sipper pump, interface cable kit, calibration standards set, and many others.    

  Model 6300 / 6305 / 6310 / 6315 / 6320D
  The entry-level spectrophotometers with great value for money.
  • Model 6300/6305
    Model 6300/6305

    Scanning UV-VIS spectrophotometer: Model 6315

    Full specifications
    (0.9 MB)
    The Model 6300 is designed to provide the user with a high quality, low cost measurement system for routine analysis. A customised LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
  • Non-scanning
  • 8/6nm bandwidth
  • Easy to use
  • Versatile sampling system
  • Full interfacing capability
  • G.L.P. compliant.
  • Simple keypad layout and operating protocols ensure reliable operation by unfamiliar users.
  • An impressive optical performance minimises the stray light by the automatic activation of internal filters, whilst the narrow 8nm bandwidth provides the high degree of selectivity essential for most analytical situations. A precision stepper motor gives excellent positional control for the optical grating ensuring wavelength selection is both accurate and highly repeatable.
  • Calibration curves producing non-linear results can also be accommodated using in-built software and the multi-cell changer. Up to seven data points can be determined automatically and used to construct a calibration curve. A variety of statistical methods are available to ensure a close correlation to all curve shapes.
  • A versatile sampling system comprising a large cell chamber and the variable length cuvette holder allow 10-100mm cells to be accommodated with ease, therefore changing of the sample configuration is quick and simple. Additional sampling flexibility can be gained using 10-25mm diameter test tubes or the optional 4 position cell holder.
  • Full interfacing capability using RS232 interfacing or an analogue output is provided as standard. Utilising the RS232 facility allows results to be down loaded via the front panel print key. The bi-directional interface also allows remote interrogation and control of the 6300.
  • Traceable calibration standards provide the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). The 6300 complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility.
  • The xenon lamp source (6305) offers a broad spectral source and extended life, therefore minimising the running costs of the product over its lifetime. The key feature of the lamp is that 40% of the energy of the lamp is emitted below 400nm, with intensity at 260nm which means an extra 5-10 times energy in the UV region compared to deuterium lamps. This makes the 6305 an ideal instrument for protein peptide or DNA studies.
  • A 3 point wavelength calibration is performed each time the 6305 is switched on, by looking at the fixed emission lines of the xenon lamp. This ensures the certainty of wavelength setting (247, 528 and 824nm) and provides the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). The 6305 complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility.
  • The model 6310 is a real visible range scanning spectrophotometer.
  • The Model 6315 completes the 63 Series product range. Building on the platform of the highly successful 6310, the model 6315 uses a pulsed xenon lamp to extend the wavelength range to the UV region. The 6315 is an advanced measuring system with modes for Photometrics, Spectrum Scanning, Kinetics, Concentration and Quantitation and will meet the demands of a wide range of applications in areas such clinical, veterinary, environmental and general QC testing.
  • The Model 6320D is designed to provide the user with a high quality, low cost measurement system for routine analysis. The 6320D has modes for Absorbance, %T and Concentration measurement. Calibration is performed against a blank (Abs or %T) and a standard or factor for Concentration. Wavelength selection is made electronically via a finely geared stepper motor with a displayed resolution of 1nm.
  • A customised LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
  • Easy to use
  • Versatile sampling system
  • Full interfacing capability
  • G.L.P. compliant 320-1000nm/8nm SBW
  • Domed lid enables use with tall sample tubes

JW632501
JW630501
JW631001
JW635001
JW631501
reference
Model 6320D
Model 6300
Model 6310
Model 6305
Model 6315
name
320 - 1100
320 - 1100
320 - 1100
198 - 1100
198 - 1100
(nm)
wavelength
1
1
1
1
1
(nm)
resolution
8

8

8
6
8
(nm)
bandwith
< 0.5*
< 0.5*
< 0.5*
< 0.5*
< 0.5*
(%T)

stray light *@340 & 220nm

ppm, mg/l, g/l, M, blank
ppm, mg/l, g/l, M, blank
ppm, mg/l, g/l, M, blank
ppm, mg/l, g/l, M, blank
ppm, mg/l, g/l, M, blank
units
no
no
yes
no
yes
( - )
scanning
yes
yes
yes
yes
yes
( - )
GLP
yes
yes
yes
yes
yes
( - )
RS-232
 
Best price!
     
 
(CHF)
price
Model 6320D
Model 6300/6305
Spectrophotometer Model 6310: fully PC controllable scanning spectrophotometer at low cost.
Model 6300/6305
Scanning UV-VIS spectrophotometer: Model 6315
only!
 
         
  Mains lead, pack 100 disposable cuvettes, 10 x 10 mm cell holder, interface cable, application software on CD-Rom (except 6320D) and instruction manual.   included
  Option accessories sipper pump, 4 position cell holder, test tube block, calibration standards set, micro-cuvettes and many others.    
     

Nous avons beaucoup d'autres produits. Veuillez ne pas hésiter à nous contacter.

 
     
We have many other products. Do not hesitate to contact us.
 
     
Change in specifications and prices without notice.
 
     
Errors and ommisions excepted. Pictures are not contractual.
 
     
 Last Update:
 
     
Copyright © 2001, ALYS Technologies SA